Equipment Name: TGA/DTA/DSC Thermal Analyzer DSC Range: DSC Range: 0 ~ ± 500mW
Temperature Range: Room Temperature ~ 1550 ℃ Warranty Time: 12 Months And Life-time Technical Support

1250C High Temperature TGA/DSC Instruments TGA DSC Simultaneous Thermal Analyzer, High Temperature Metal Differential Thermal Analyzer TGA DSC

 

Application

STA200 STA300 Synchronous thermal analysis thermal analyzer is combined with differential thermal analysis TGA and DTA or differential scanning calorimetry DSC, and TGA and DTA and DSC were obtained by using the same sample in the same measurement. It mainly measures the physical and chemical changes related to heat, such as the melting point of the material, heat of fusion, crystallization and crystallization heat, phase change heat, thermal stability (oxidation induced period), glass transition temperature, adsorption and desorption, Composition analysis, decomposition, combination, dehydration, additives and other changes in the study. The versatile design with rich options is the ideal tool in your lab. The instruments are widely used in most materials, including plastics, rubber, synthetic resins, fibers, coatings, grease ceramics, cement, glass, refractories, fuels, pharmaceuticals, foodstuffs, refractories and so on.


The following characteristics of the measurement and study materials:
DSC: melting, crystallization, phase change, reaction temperature and reaction heat, heat of combustion, specific heat.
TGA: thermal stability, decomposition, oxidation and reduction, adsorption desorption, free water and crystal water content, composition ratio calculation.

 
Features

1. Furnace heating using nickel-cadmium alloy double-wound wire system to reduce interference, but also high temperature.
2. Tray sensor, using precious metal nickel-cadmium alloy Seiko build, with high temperature, anti-oxidation, corrosion resistance and so on.
3. Power supply, circulation and cooling part of the host separate to reduce the heat and vibration on the microbalance impact.
4. Using open cover structure, easy to operate. Move the furnace body to put the sample operation is very difficult, easy to cause the sample rod damage.
5. The host uses water thermostat to isolate the thermal effect of the heating furnace on the chassis and the microbolometer.
6. According to customer requirements to replace the furnace.

 

Technical parameters

Temperature range room temperature ~ 1150 ℃ room temperature ~ 1250 ℃ room temperature ~ 1350 ℃

2. Temperature resolution: 0.1 ℃
3. Temperature fluctuation: ± 0.1 ℃
4. Heating rate: 1 ~ 80 ℃ / min
5. Temperature control: heating, constant temperature, cooling
6. Constant temperature: 0 ~ 300min arbitrarily set
7. Cooling time: 15min (1000 ℃ ~ 100 ℃)
8. Balance measurement range: 1mg ~ 2g can be extended to 5g
9. DSC range: 0 ~ ± 500mW
10. DSC resolution: 0.01mW
11. Sensitivity: 0.01mW
12. Constant temperature: 0 ~ 300min arbitrarily set
13. Display: 24bit color, 7 inch LCD touch screen display
14. Atmosphere device: built-in gas flow meter, including two gas switching and flow size control
Atmosphere: inert, oxidizing, reducing, static, dynamic
15. Software: intelligent software can automatically record the TG curve for data processing, print the experimental report
16. Data interface: standard USB interface
17. Power: AC220V 50Hz (AC110V,60Hz)

High Temperature Metal Powder Differential Synchronous Thermal Analyzer TGA DSC 0

High Temperature Metal Powder Differential Synchronous Thermal Analyzer TGA DSC 1

FAQ 1. Are you a factory or trading company?

We are a factory.

 

FAQ 2. Can you supply OEM?

OEM is available.

 

FAQ 3. What's the MOQ ?

(1). MOQ is 1 piece. The disposable supplies order usually at least 1 box.

 

FAQ 4. How about the order processing and lead time?

After order confirmation and receive the advance payment, we will prepare the machines and goods. Usually could ready within 10 working day, when dispatch, will inform client and send the documents for client making import customs clearance.

 

FAQ 5. What quality will be ensured?

100% new and quality inspection before delivery from factory.

Stable export box for good package.

 

FAQ 6. Can you guide the working?

The machine will deliver with English display, English manual and video for installation and operation.

 

FAQ 7. How can your engineer replace parts if they are not beside the machine?

Bonnin’s engineer could provide the solutions by email and video. In warranty period, we can send spare parts for free and life-time technical support for spare supply.

 

Contact Details
Aimee Wang

Phone Number : +86 13308639527

WhatsApp : +8613308639527